11. SCPI commands scheduled for upcoming releases

11. SCPI commands scheduled for upcoming releases

 

Please note that the following list is preliminary.

 

SCPI command

Description

DCL

Requires the client (controller) to send a “DCL\n” string

*SRE

Sets the value of the Service Request Enable register
*WAI Waits until all pending commands are completed

CALibration

:TEMPerature

[:DATA] {<new value>}

Enters the calibration value

INSTrument

:COUPle

:TRIGger {<mode>}

Selects a coupling between channels trigger systems

OUTPut

:DELay

:ON {<time>}

Sets the delay time for turning the output on

:OFF {<time>}

Sets the delay time for turning the output off

:DPRog {<bool>}

Controls down-programmer circuit

[SOURce[<n>]]

:CURRent

:SLEW

:FALLing

Sets the falling current slew rate

:RISing

Sets the rising current slew rate

:VOLTage

:SLEW

:FALLing

Sets the falling voltage slew rate

:RISing

Sets the rising voltage slew rate

SYSTem

:COMMunicate

:ETHernet

Ethernet communication parameters

:CONTrol?

Queries communication port for SRQ handling

:HOSTname {<name>}

Sets the Ethernet communication host name

:DIGital

:TOUTput

:BUS[:ENABle] {<Bool>}

Enables/disables BUS-generated triggers on digital pins

:ERRor

:ALL?

Queries the error/event queue for all the unread items

:CODE[:NEXT]?

Queries the error/event queue for the next item code

:TIME

:TIMer

[:STATe]

Sets the internal timer state

:COUNt

Queries the current value of the internal timer