The PSU’s triggering system allows a change in output voltage, current or start internal data logging when receiving a trigger, to select a trigger source, and to insert a trigger. Triggering the PSU is a multi-step process, for example:
- An output has to be selected (the INSTrument:SELect command) following by configuring the PSU for the triggered output level by using CURRent:TRIGgered and VOLTage:TRIGgered commands.
- The source from which the PSU will accept the trigger must be specified. The PSU could accept e.g. a BUS (software) trigger or an IMMediate trigger from the remote interface.
- The time delay between the detection of the trigger on the specified trigger source and the start of any corresponding output change can be programmed if needed. Such time delay is valid only for the BUS trigger source.
- Trigger programming is completed by providing an INITiate[:IMMediate] command. If the IMMediate source is selected, the selected output is set to the triggered level immediately. But if the trigger source is the BUS, the PSU is set to the triggered level after receiving the *TRG command.
SCPI command |
Description |
TRIGger |
|
[:SEQuence] |
|
Starts the trigger immediately | |
Sets the time delay between the detection of a trigger event and the start of any corresponding trigger action | |
:EXIT |
|
Sets channels condition when LIST execution stopped | |
Sets the trigger source | |
:DLOG |
|
Sets the internal data logger trigger source |
5.16.1. TRIGger[:SEQuence][:IMMediate]
Syntax |
TRIGger[:SEQuence][:IMMediate] |
Description | This event command causes a defined LIST to immediately start without the selected trigger occurring. |
Usage example |
TRIG |
Related Commands |
*TRG |
5.16.2. TRIGger[:SEQuence]:DELay
Syntax |
TRIGger[:SEQuence]:DELay {<delay>} TRIGger[:SEQuence]:DELay? |
|||
Description | This command sets the time delay between the detection of an event on the specified
trigger source and the start of any corresponding trigger action on the PSU output. |
|||
Parameters |
Name |
Type |
Range |
Default |
<delay> |
NR1|Discrete |
0 – 3600|MIN|MAX |
MIN |
|
Return |
The query command returns the programmed delay in seconds. | |||
Usage example |
TRIG:DEL 10 |
5.16.3. TRIGger[:SEQuence]:EXIT:CONDition
Syntax |
TRIGger[:SEQuence]:EXIT:CONDition {<condition>} TRIGger[:SEQuence]:EXIT:CONDition? |
|||
Description | This command sets channels condition when LIST execution is not prematurely stopped (e.g. with ABORt command or by user action).
Use [SOURce[<n>]]:LIST:COUNt to set finite number of LIST loops. |
|||
Parameters |
Name |
Type |
Range |
Default |
<condition> |
Discrete |
OFF|FIRSt|LAST|STANdby |
OFF |
|
Return |
The query command returns the programmed exit condition. | |||
Usage example |
TRIG:EXIT:COND STAN |
|||
Related Commands |
ABORt
INITiate [SOURce[<n>]]:LIST:COUNt [SOURce[<n>]]:CURRent:MODE [SOURce[<n>]]:VOLTage:MODE |
5.16.4. TRIGger[:SEQuence]:SOURce
Syntax |
TRIGger[:SEQuence]:SOURce {<source>} TRIGger[:SEQuence]:SOURce? |
|||
Description | This command selects the source from which the PSU will accept a trigger.
When the trigger source is set to BUS, the *WAI command can ensure the synchronization. After executing the *WAI command, the PSU will only execute new command when all the pending operations are completed. Also when the trigger source is set to BUS, you can use the *OPC command to report that the operation is completed. The *OPC? command will return “1” to the output buffer and the *OPC command will set the bit 0 (OPC bit, operation complete) in the standard event register when the operation is finished.
The wait for the BUS, EXTernal, or KEY trigger can be bypassed by sending the TRIGger[:SEQuence][:IMMediate] command.
The APPLy command automatically sets the source to IMMediate. |
|||
Parameters |
Name |
Type |
Range |
Default |
<source> |
Discrete |
BUS|IMM|MAN|PIN1 |
– |
|
Return |
The query command returns the programmed trigger subsystem source. | |||
Usage example |
TRIG:SOUR BUS TRIG:SOUR? BUS |
|||
Related Commands |
*OPC
*RST *TRG *WAI ABORt APPLy INITialize TRIGger[:SEQuence][:IMMediate] |
5.16.5. TRIGger:DLOG[:IMMediate]
Syntax |
TRIGger:DLOG[:IMMediate] |
Description | The command sends an immediate trigger signal to the data logger. This will trigger the internal data log session regardless of the selected trigger source. You must initiate (see the INIT:DLOG command) the data logger before you trigger it. |
Usage example |
TRIG:DLOG |
Related Commands |
*TRG
INITialize:DLOG |
Syntax |
TRIGger:DLOG:SOURce {<source>} TRIGger:DLOG:SOURce? |
|||
Description | The command selects the trigger source for the data logger in the same fashion as the TRIGger[:SEQuence]:SOURce command. | |||
Parameters |
Name |
Type |
Range |
Default |
<source> |
Discrete |
BUS|IMM|MAN|PIN1 |
– |
|
Return |
The query command returns the programmed trigger subsystem source. | |||
Usage example |
TRIG:DLOG:SOUR PIN1 TRIG:SOUR? PIN1 |
|||
Related Commands |
INITialize